Heat Pumps in Cold Weather: Performance, Costs, and Winter Strategies

Learn how a heat pump performs in cold weather, what “cold-climate” really means, how to size and operate systems in winter, and how to cut bills with incentives and smart settings.

Cold climates no longer rule out electric heating. Today’s cold-climate heat pumps deliver reliable heat even when temperatures plunge. This guide explains how a heat pump works in cold weather, what ratings matter, how to size it correctly, and how to operate it for comfort and savings. It also covers incentives, costs versus gas or oil, and practical winter tips to keep systems running strong.

How Heat Pumps Work In Cold Weather

A heat pump moves heat rather than making it. In winter, the outdoor unit extracts heat from cold air and transfers it indoors via refrigerant. Even below 0°F, there is usable heat energy in outdoor air.

Modern systems use inverter-driven compressors that modulate output, improving comfort and efficiency at low temperatures. Many cold-climate models add enhanced vapor injection (EVI) and optimized refrigerant controls to sustain capacity during deep cold.

Efficiency is expressed as COP (Coefficient of Performance), the ratio of heat delivered to electric input. A COP of 2.5 means 2.5 units of heat per 1 unit of electricity. COP declines as outdoor temperatures drop, but advanced units maintain useful efficiency well below freezing.

Defrost cycles are normal. When outdoor coils frost, the system briefly reverses to melt ice, then returns to heating. Expect a short pause in warm air during defrost; properly designed systems minimize comfort impact.

What “Cold Climate” Means: Ratings And Standards

Not all heat pumps are equal in winter. Look for products explicitly designed and tested for cold conditions and verified by credible programs.

Key Ratings

  • HSPF2 (Heating Seasonal Performance Factor 2): Seasonal heating efficiency under updated test conditions. Higher is better. Ducted ENERGY STAR minimum is typically 7.8 HSPF2 or higher; premium cold-climate models exceed this.
  • SEER2: Cooling efficiency. Useful for summer but less relevant to winter performance.
  • COP At 5°F: A critical snapshot of low-temperature efficiency. Strong cold-climate heat pumps can deliver COPs around 1.7–2.5 at 5°F depending on model and load.
  • Low-Temp Capacity: Look for published capacity at 5°F and 17°F. Many cold-climate systems maintain a large share of rated capacity at 5°F; some are near full rated output.

Programs And Directories

  • ENERGY STAR Cold Climate: Identifies models that meet rigorous low-temperature performance criteria, including substantial capacity and efficiency at 5°F. See ENERGY STAR Cold Climate.
  • NEEP Cold Climate Heat Pump List: A regional database with low-temperature capacity and COP data useful for specification. See NEEP ccASHP.
  • AHRI Directory: Verify matched system ratings for specific outdoor and indoor unit combinations at the AHRI Directory.

Bottom line: For a heat pump in cold weather, choose a cold-climate-certified model with strong 5°F capacity and published low-temperature COP data.

Performance At Low Temperatures: What To Expect

As the outdoor temperature falls, a heat pump’s capacity and efficiency decline. Cold-climate models are engineered to flatten that decline, maintaining comfort and reasonable operating costs in subfreezing conditions.

  • Typical capacity retention: Many cold-climate systems deliver 70–100% of nominal capacity at 5°F, with some able to maintain robust output below that point.
  • Typical COP range: Around 2.5–3.5 at 35°F, 1.7–2.5 at 5°F, and 1.3–2.0 around 0°F depending on model and load conditions.
  • Operating range: Numerous products heat down to -5°F to -13°F, and some extend below that with reduced capacity.

Expect a defrost plume (steam-like vapor) during thaw cycles in humid cold. This is normal. Outdoor units should be elevated to keep the coil and fan clear of snowdrifts and meltwater.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

In multi-zone ductless systems, winter performance can suffer if only some indoor heads call for heat. For cold climates, single-zone units or appropriately sized multi-zone systems with good turn-down and control strategies are recommended.

Sizing And Design For Cold Climates

Correct design is as important as the equipment. Oversizing reduces efficiency and can cause short cycling; undersizing increases auxiliary heat use. Aim for a balanced design using industry standards.

  • Manual J (Load Calculation): Determine room-by-room heating loads based on insulation, windows, infiltration, and climate. Avoid rule-of-thumb sizing.
  • Manual S (Equipment Selection): Choose a heat pump whose 5°F capacity closely matches the load at that temperature. For deep-cold regions, design around a reasonable balance point where limited auxiliary heat covers rare extremes.
  • Manual D (Duct Design): Ensure ducts are sized, sealed, and insulated to deliver quiet, efficient airflow. In existing homes, duct improvements can make a major comfort difference.

Balance point is the outdoor temperature where the heat pump output equals the building load. Below this temperature, the system may modulate to maximum and, if needed, add auxiliary heat. Good design keeps auxiliary heat use modest without oversizing the heat pump.

For homes without ducts, ductless mini-splits can be highly efficient. Use enough indoor heads to cover loads but avoid excessive zoning that forces the outdoor unit to run inefficiently on very small calls.

Backup Heat Options: Electric Resistance Vs Dual-Fuel

Backup heat ensures comfort during extreme cold and defrost cycles. The right approach depends on energy prices, decarbonization goals, and existing equipment.

Electric Resistance (Strip Heat)

  • Pros: Simple, fully electric, low maintenance, integrates cleanly with a heat pump air handler.
  • Cons: High operating cost (COP ≈ 1). Best used sparingly with temperature lockouts and staged control.
  • Smart control: Set auxiliary lockout temperatures so strip heat engages only when necessary, and configure staged strips (e.g., 5 kW increments) to limit demand spikes.

Dual-Fuel (Hybrid) With Gas Or Propane Furnace

  • Pros: Uses the heat pump for most hours; switches to combustion heat during extreme cold or high electric prices. Can reduce bills where gas is inexpensive.
  • Cons: More complex controls; continued reliance on fossil fuel. Carbon benefits depend on grid mix and switchover settings.
  • Set switchover temperature based on economics: compare heat pump cost per BTU (using COP vs temperature) to furnace cost per BTU (including efficiency and gas price).

In all cases, a well-sealed, insulated home lowers the need for auxiliary heat. Weatherization often delivers the fastest payback and increases comfort.

Defrost, Ice, And Snow Management

Ice management is central to winter reliability. The outdoor unit will periodically reverse cycle to melt frost; water drains from the base pan and may refreeze nearby.

  • Mounting height: Elevate the outdoor unit 12–18 inches (or more in snowy regions) to stay above drifts and allow drainage.
  • Clearances: Maintain manufacturer-specified rear and side clearances for airflow. Keep at least several feet clear in front of the fan discharge.
  • Base pan heater: In icy climates, models with integrated pan heaters help prevent ice buildup that can damage the fan or coil.
  • Drainage: Direct meltwater away from walkways and foundations. In very cold weather, consider a gravel bed under the unit.
  • Snow control: Install awnings or shields to block roof avalanches and drifting—without restricting airflow.

Defrost frequency increases in humid cold and near-freezing conditions. Short, regular defrosts are normal. Frequent long defrosts can signal airflow or sensor issues that warrant service.

Operating Tips To Save Money In Winter

  • Thermostat strategy: Use modest setpoints and small setbacks (2–4°F). Large setbacks can trigger auxiliary heat and erase savings.
  • Fan mode: Keep the fan on “Auto.” Continuous “On” can increase drafts and energy use in winter.
  • Filter care: Replace or wash filters regularly. A MERV 8–13 filter balances air quality and airflow; check manufacturer guidance.
  • Smart thermostats: Choose models that control auxiliary lockout, support dual-fuel logic, and can optimize preheating for time-of-use rates.
  • Doors and zoning: Keep doors open where a single indoor unit serves multiple rooms so heat circulates. Use dedicated heads for closed-off rooms.
  • Water heater: Consider a heat pump water heater; it can offload some space-heating during shoulder seasons in basements.
  • Maintenance: Keep outdoor coils clear of leaves, check condensate pathways, and schedule annual professional service.

Cost And Payback: Real-World Numbers

The cost to heat with a heat pump in cold weather depends on electricity price and COP. Gas, propane, or oil costs depend on fuel prices and furnace efficiency.

Delivered Heat Cost Examples

1 MMBtu ≈ 293 kWh. Delivered cost per MMBtu accounts for efficiency (COP for heat pumps; AFUE for furnaces).

Fuel/Condition Assumptions Delivered Cost Per MMBtu
Heat Pump (COP 2.5) $0.15/kWh $17.6
Heat Pump (COP 2.0) $0.15/kWh $22.0
Heat Pump (COP 1.7) $0.20/kWh $34.5
Electric Resistance $0.15/kWh, COP 1.0 $44.0
Natural Gas Furnace $1.50/therm, 95% AFUE $15.8
Propane Furnace $2.50/gal, 92% AFUE $29.7
Fuel Oil Furnace $4.00/gal, 85% AFUE $34.1

Takeaway: Where electricity is moderate and COP stays above ~2, a heat pump is cost-competitive with gas and usually beats propane or oil. In deep cold, efficiency declines, but annualized costs often remain favorable because many heating hours occur above 15–25°F.

Simple Payback Example

Replacing an oil furnace in the Northeast with a cold-climate heat pump: if annual heat is 60 MMBtu, oil at $34/MMBtu costs about $2,040. A heat pump averaging $22/MMBtu costs about $1,320. Annual savings ≈ $720 before incentives. With a $2,000 federal tax credit and $1,000 utility rebate, net installed cost drops, shortening payback.

Incentives, Codes, And Refrigerant Changes

Well-chosen incentives can significantly reduce upfront cost and improve payback for a heat pump in cold weather.

Federal Tax Credits

  • Energy Efficient Home Improvement Credit (25C): 30% of installed cost, up to $2,000 per year for qualified heat pumps through 2032. See the IRS and ENERGY STAR guidance: ENERGY STAR Tax Credits.

Home Energy Rebates (IRA)

  • The Inflation Reduction Act funds state-run Home Energy Rebates, including Home Efficiency (HOMES) and Home Electrification and Appliance Rebates (HEAR). Availability, income eligibility, and amounts vary by state. Check your state energy office and DOE Home Energy Rebates.

Utility And State Programs

  • Many utilities offer seasonal rebates for cold-climate models. Search the DSIRE database: DSIRE, or your utility’s website.

Refrigerants And Codes

  • Lower-GWP Refrigerants: The industry is transitioning from R‑410A to R‑454B or R‑32 (mildly flammable A2L) to reduce climate impact. Local codes have been updated to permit safe installation with appropriate training and protections.
  • New Test Metrics: Since 2023, SEER2 and HSPF2 replaced SEER/HSPF, slightly lowering published values for the same equipment due to stricter test conditions. Compare within the SEER2/HSPF2 framework.

Action step: Confirm your contractor’s familiarity with A2L refrigerants, permit requirements, and any additional ventilation or sensor provisions for indoor equipment.

Choosing The Right Cold-Climate Heat Pump

Selection should prioritize low-temperature performance, right-sizing, and quality installation. A checklist helps narrow choices.

  • Certification: ENERGY STAR Cold Climate and/or listing on NEEP’s database.
  • Low-Temp Data: Published capacity and COP at 5°F and 17°F, not just 47°F. Aim for high capacity retention and COP ≥ ~1.75 at 5°F where possible.
  • Modulation Range: A broad turn-down ratio improves comfort and efficiency during mild weather.
  • Sound Levels: Check dB ratings and consider placement relative to neighbors and bedrooms.
  • Controls: Thermostats that manage auxiliary lockout, dual-fuel switchover, and time-of-use rates.
  • Warranty And Support: Look for strong parts and compressor warranties and local service availability.
  • Installer Quality: Require Manual J/S/D, AHRI-matched equipment, proper refrigerant charging, and commissioning reports.

For existing ducts, consider a cold-climate ducted heat pump or a dual-fuel pairing. For homes without ducts, single-zone or carefully designed multi-zone mini-splits can heat efficiently across rooms.

Regional Considerations And Grid Impacts

Climate, electricity rates, and grid policies vary widely across the U.S., shaping the best strategy for a heat pump in cold weather.

  • Northeast & Upper Midwest: Cold-climate models paired with weatherization perform well and often cut costs versus oil or propane. Dual-fuel may be economical where gas is cheap.
  • Mountain West & Northern Plains: Elevate outdoor units above snowpack and choose models with strong 5°F capacity. Consider wind-driven snow when siting.
  • Pacific Northwest: Moderate electricity rates and milder winters favor all-electric operation with minimal auxiliary heat.
  • Time-of-Use (TOU) Rates: Preheat homes before peak price windows; let indoor temperature float a degree or two to ride through peaks without auxiliary heat.
  • Demand Response: Smart thermostats can shift load to support grid stability, sometimes earning bill credits.

Emissions: Even on mixed grids, cold-climate heat pumps often reduce CO₂ compared to oil or propane, and increasingly compared to gas as grids add renewables. Emissions benefits grow over a system’s 15–20-year life as the grid decarbonizes.

Troubleshooting Common Winter Issues

Cold weather can reveal installation or maintenance gaps. Most issues have straightforward fixes.

  • Unit runs constantly: Normal during cold snaps. Verify filters, registers, and that auxiliary heat is staged and locked out appropriately.
  • Frequent defrost cycles: Check for blocked airflow, dirty coils, or sensors. Ensure outdoor clearances and consider a base pan heater in icy climates.
  • High bills in a cold month: Review thermostat setbacks and auxiliary heat use. Slightly raise auxiliary lockout temperature if the heat pump can carry more of the load.
  • Outdoor unit encased in ice: Power down and clear obstructions; ensure drainage; call a technician to inspect defrost control and pan heater.
  • Drafty rooms: Balance dampers, seal ducts, and consider adding an indoor head or improving insulation in problem areas.

If performance seems off, ask the contractor for commissioning data: static pressure, supply/return temperatures, refrigerant superheat/subcooling, and auxiliary heat staging.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

Myths And Facts About Heat Pumps In Cold Climates

  • Myth: Heat pumps do not work below freezing. Fact: Cold-climate heat pumps deliver heat efficiently well below 32°F and can operate near or below 0°F.
  • Myth: You must always keep a furnace. Fact: Many homes run all-electric with a properly sized heat pump and modest electric backup.
  • Myth: Defrost means something is broken. Fact: Regular defrost cycles are expected; only prolonged or constant defrost suggests a problem.
  • Myth: Large nighttime setbacks save money. Fact: Big setbacks often trigger auxiliary heat and reduce savings; use small, strategic setbacks.

Design Example: Setting A Balance Point And Lockouts

Consider a 2,000-square-foot home in Minneapolis with a 5°F heat loss of 36,000 BTU/h. A cold-climate 3-ton unit might provide 34,000 BTU/h at 5°F and 48,000 BTU/h at 17°F.

  • Balance point: Near 5–8°F, where heat pump output roughly equals the load.
  • Auxiliary heat: Install 5–10 kW of strips for rare extremes; set a lockout around 0–5°F if the heat pump can hold the load, or allow staged strips to add only what’s needed.
  • Defrost control: Ensure outdoor coil sensors and pan heater are functional to avoid ice buildup.

This design keeps most heating hours on the heat pump, with auxiliary heat covering dips without oversizing the main system.

Maintenance Essentials For Winter Reliability

  • Preseason check: Clean outdoor coil, confirm clearances, verify refrigerant charge, and test defrost function.
  • Filter schedule: Replace filters every 1–3 months in winter depending on dust and pets.
  • Indoor airflow: Verify registers are open and not blocked by rugs or furniture; measure temperature rise across the coil.
  • Electrical: Inspect connections and breakers; confirm strip heat staging and thermostat configuration.
  • After storms: Clear snow/ice and ensure the fan spins freely before restarting.

How To Compare Models For Your Home

Use manufacturer submittals and third-party listings to make apples-to-apples comparisons for a heat pump in cold weather.

  • Look up: Capacity and COP at 5°F and 17°F, turn-down ratio, sound levels, and defrost strategy.
  • Verify: AHRI-matched indoor and outdoor units; ensure ducts can handle required airflow at low and high speeds.
  • Ask for: A written load calculation, model-specific performance tables, and a control strategy showing auxiliary lockout and (if applicable) dual-fuel switchover.

If two models are similar, choose the one with better 5°F capacity retention and lower sound, provided the installer has strong local support and parts access.

Resilience: Outages, Backup Power, And Comfort

Winter storms can cause outages. Plan for resilience with load management and backup power.

  • Generator or battery: A modest backup system can power a single-zone mini-split or a central heat pump at reduced speed, along with critical loads.
  • Load shedding: Stage strip heat and consider disabling it during backup operation to avoid overloading.
  • Envelope first: Better insulation and air sealing slow heat loss, extending safe indoor temperatures during outages.

Some heat pumps support grid-interactive controls, allowing preheating before storms and automatic setpoint adjustments to conserve battery power.

Where To Learn More And Verify Specifications

Frequently Asked Questions About Heat Pumps In Cold Weather

How low can a heat pump heat? Many cold-climate models operate effectively to -5°F to -13°F, with some below that at reduced capacity. Always check the manufacturer’s low-temperature capacity.

Will a heat pump raise my bills? It depends on electricity and fuel prices and your home’s efficiency. Against oil or propane, bills often drop. Against inexpensive natural gas, costs can be similar, with savings growing in milder hours.

Do I need a backup furnace? Not necessarily. Many homes run all-electric with limited strip heat. Dual-fuel may be chosen for economics or existing equipment reuse.

Are mini-splits good for whole-house heating? Yes, when designed correctly. Use enough indoor units to cover loads, prioritize single-zone performance in key spaces, and manage doors and airflow.

Is defrost a problem? No. Brief defrost cycles are normal. Persistent ice indicates a drainage, airflow, control, or heater issue that needs attention.

What about refrigerants? New systems increasingly use lower-GWP A2L refrigerants like R‑454B or R‑32. Qualified installers and updated codes ensure safe installation and service.

Can I use set-backs overnight? Small setbacks are fine. Large setbacks often trigger auxiliary heat and reduce efficiency in the morning recovery.

How important is weatherization? Very. Air sealing and insulation reduce load, improve comfort, and let the heat pump carry more hours without backup heat, especially during cold snaps.

How to Get the Best HVAC Prices

  • Firstly, keep in mind that installation quality is always the most important thing for residential HVAC project. So never sacrifice contractor quality for a lower price.
  • Secondly, remember to look up the latest rebates as we talked above.
  • Thirdly, ask for at least 3 bids before you make the decision. You can click here to get 3 free estimates from your local contractors, and this estimate already takes rebates and tax credit into consideration and filter unqualified contractors automatically.

Lastly, once you chose the right contractor, remember to use the tactics from this guide: Homeowners Tactics When Negotiating with HVAC Dealer to get the final best price.

Written by

Rene has worked 10 years in the HVAC field and now is the Senior Comfort Specialist for PICKHVAC. He holds an HVAC associate degree and EPA & R-410A Certifications.