Heat Pump Reset Button: Location, Safe Reset Steps, and Troubleshooting

A heat pump reset button can clear a temporary fault and get heating or cooling back fast. But not every system has one, and pressing the wrong switch can mask bigger problems. This guide explains where to find a heat pump reset button, how to reset a heat pump safely, and what to do if it keeps tripping.

What A Heat Pump Reset Button Really Does

Homeowners search for a “heat pump reset button” expecting a single magic fix. In reality, modern systems use protections and lockouts that may or may not include a physical reset button. Knowing the difference helps prevent damage.

Most residential heat pumps protect the compressor with control boards and pressure switches. Some switches are manual reset and require a press to clear. Others are auto reset and clear once the fault condition ends.

Common “reset” points include a high-pressure safety on the outdoor unit, a thermal overload on the indoor blower motor, and a control-board lockout that clears by power cycling. Many systems rely solely on power cycling and do not include a user-facing reset button.

Quick Safety Checklist Before Pressing Any Reset

Electrical and refrigerant protections exist to prevent damage. Before touching a reset switch, follow a safety checklist to avoid injury and misdiagnosis.

  • Shut Off Power: Turn the thermostat OFF. Switch the heat pump breaker OFF at the main panel and the outdoor disconnect OFF.
  • Wait 5 Minutes: Allow the compressor’s internal pressures to equalize and electronics to discharge.
  • Do Not Bypass Safeties: Never jump wires or hold down contactors. Press only labeled reset buttons.
  • Avoid Wet/Icy Conditions: Don’t open panels in rain or while coils are iced. Let ice melt first.
  • Know When To Stop: If protection trips again quickly, do not repeatedly reset. Call a licensed HVAC technician.

Where To Find A Heat Pump Reset Button

Location varies by system type, brand, and age. Some do not include any manual reset. Use model-specific documentation if available.

Outdoor Unit (Condenser/Heat Pump)

Some outdoor units include a manual high-pressure switch. It is often a small button near the refrigerant service area or on a control panel inside the access door.

Brands vary. Select models from Trane, Carrier, Lennox, and Rheem may use manual or auto-reset high-pressure switches. Newer units increasingly use auto-reset and control-board lockouts instead of a pressable switch.

Indoor Unit (Air Handler Or Furnace With Coil)

Air handlers with PSC or ECM blowers may include a blower motor thermal reset. This can be a button on the motor or an inline protector. It trips with overheating due to blocked airflow or motor faults.

Some furnaces or air handlers include a control board reset that is accomplished by power cycling rather than a button. The board may show error codes via LED flash patterns.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

Mini-Split (Ductless) Systems

Mini-splits rarely have a user-accessible reset button on the outdoor unit. Instead, they show error codes via blinking lights and may offer a remote-control reset or require a power cycle to clear lockouts.

Indoor heads sometimes include a recessed “reset” or “ACL” button near the filter area. Manufacturer guides for Mitsubishi, Daikin, LG, and Fujitsu detail model-specific reset procedures.

Package Units

Packaged heat pump units may include service-only manual reset switches behind panels. Homeowners should rely on thermostat and breaker resets and leave panel access to professionals.

Heat Pump Reset Button Locations At A Glance

Component Reset Type Typical Location Notes
High-Pressure Switch Manual Or Auto Outdoor unit, near service valves or behind panel Manual requires a press; auto clears when pressure normalizes
Blower Motor Thermal Manual On motor housing or inline on air handler Trips on overheating from low airflow or motor issues
Control Board Lockout Power Cycle Board inside outdoor or indoor unit Clears by cutting power for 2–5 minutes
Mini-Split Indoor Head Remote/Soft Reset Recessed button or via remote Check model manual; error codes guide diagnosis

Step-By-Step: How To Reset A Heat Pump Correctly

Because hardware varies, the safest universal reset is a controlled power cycle. If a physical heat pump reset button exists, use it only after power is off and the reason for tripping is addressed.

Method 1: Safe Power Cycle (Works For Most Systems)

  1. Set the thermostat to OFF and fan to AUTO.
  2. Turn the dedicated heat pump breaker OFF at the panel. Also switch off the outdoor disconnect if present.
  3. Wait 5 minutes to allow compressor equalization and control-board reset.
  4. Restore power: turn ON the disconnect and breaker.
  5. Set thermostat to HEAT or COOL and wait for a call. Many boards have a time delay (3–5 minutes) before starting the compressor.

Method 2: Pressing A High-Pressure Reset Button

  1. Turn power OFF at the breaker and disconnect.
  2. Inspect outdoor coil for debris. Clear leaves, cottonwood, or obstructions. Ensure at least 18–24 inches of clearance around the unit.
  3. Open the service panel only if safe and permitted. Find a small button labeled “HP”, “High Press”, or similar.
  4. Press once firmly. If it clicks, it was tripped. Do not press repeatedly.
  5. Close the panel, restore power, and test operation.

If it trips again, stop and call a pro. Repeated high-pressure trips indicate restricted airflow, overcharge, a stuck fan, or dirty coils.

Method 3: Resetting A Blower Motor Thermal Overload

  1. Turn power OFF to the air handler/furnace and confirm with a non-contact tester if available.
  2. Replace or clean the filter. Check supply and return vents for blockages.
  3. Locate the motor’s thermal reset button and press once. Some ECM motors auto-reset and have no button.
  4. Restore power and run the fan. If the motor overheats again, stop to prevent damage.

Method 4: Mini-Split Remote Or Soft Reset

  1. Turn system OFF using the remote or wall controller.
  2. If an error code is displayed, note it; this guides service.
  3. Turn OFF power at the breaker for 5 minutes, then restore.
  4. On some models, press the remote’s “Reset” or the indoor head’s recessed reset button.
  5. Restart in HEAT or COOL and monitor operation.

When A Reset Helps — And When It Will Not

A reset can resolve transient issues. Persistent trips point to underlying faults. Knowing which scenarios benefit from a reset can save time.

  • Helps: Brief power surge, temporary blocked outdoor airflow, thermostat glitch, brief icing that has melted, short cycling caused by incorrect smart thermostat settings.
  • Won’t Help: Low refrigerant charge, dirty coils, failed condenser or blower fan, bad run capacitor, stuck contactor, faulty pressure sensor, clogged condensate causing float switch trips.

Use a reset once after addressing likely causes like a dirty filter or blocked coil. If the same fault recurs, service is needed to prevent compressor damage.

Troubleshooting After A Reset: Quick Checks

If the heat pump reset button or power cycle restores operation, verify that the system is performing normally. If not, run through quick homeowner-safe checks.

  • Airflow: Replace a clogged filter. Open closed registers. Inspect return grilles for dust mats.
  • Outdoor Unit: Confirm the fan spins and blows warm air in cooling, cool air in heating. Clean coil fins with gentle water flow from inside out.
  • Thermostat: Verify mode, setpoint, and schedule. Disable extreme setback that causes rapid cycling.
  • Breaker & Disconnect: Ensure breakers remain ON. A tripping breaker can indicate a short or motor issue.
  • Condensate: In cooling, check the drain. A tripped float switch cuts operation to prevent overflow.
  • Timing: Respect compressor delays. Some boards wait 3–10 minutes before restarting after a call.

Why The High-Pressure Or Overload Trips Repeatedly

Frequent trips after pressing a heat pump reset button suggest conditions that overheat the system or starve it of airflow. Address root causes rather than repeatedly resetting.

  • Dirty Outdoor Coil (Cooling): Blocks heat rejection and elevates head pressure. Clean gently; avoid bending fins.
  • Dirty Filter Or Indoor Coil (Heating): In heating mode, the indoor coil acts as a condenser; low airflow causes high pressure and thermal trips.
  • Failed Fan Motor Or Capacitor: A non-spinning fan quickly forces pressure up. A bad capacitor is a common, fixable part.
  • Overcharged Refrigerant: Raises pressures; must be diagnosed by a technician using proper subcooling targets.
  • Low Refrigerant (Cooling): Can trigger low-pressure protections and icing. Repeated resets will not fix a leak.
  • Defrost Control Issues: In winter, a failed defrost board or sensor leads to icing and stress.
  • ECM Motor Overheating: Restricted ducts or bearings can trip internal protections even without a reset button.

Seasonal Tips: Winter Vs. Summer Behavior

Heat pumps behave differently by season. Understanding these modes helps decide whether a reset is appropriate or premature.

Cooling Season

  • High-Pressure Trips: Usually due to a dirty outdoor coil or stalled condenser fan.
  • Low-Pressure/Ice: Dirty indoor coil or filter, low charge, or very low airflow can freeze the coil. Turn system OFF and run FAN to defrost before any reset.
  • Condensate Float: A clogged drain pan will stop cooling. Clear the drain and reset after drying.

Heating Season

  • Defrost Cycles: Outdoor unit will periodically reverse to defrost. Do not reset mid-cycle; steam is normal.
  • High-Pressure Trips: Often from indoor airflow issues in heating. Replace filters and ensure registers are open.
  • Aux Heat: Heat strips or a furnace may activate if the heat pump locks out. A reset may restore heat pump operation, but verify why it locked out.

Smart Thermostats And Mini-Splits: Special Notes

Integration with modern controls can add complexity. Smart thermostats and ductless systems use timing and algorithms that interact with safety lockouts.

  • Compressor Protection Delays: Many thermostats include an anti-short-cycle delay. Respect the delay rather than repeatedly toggling power.
  • Minimum Run/Off Times: Configure Nest/Ecobee to avoid short cycles that can trigger safeties.
  • Outdoor Lockouts (Dual Fuel): Some systems switch to gas below a set temperature. A “no heat” symptom may be a control setting rather than a fault.
  • Mini-Split Error Codes: Reference the code chart in your manual. Codes often identify exact faults (fan, sensor, pressure). Reset only after addressing the root cause.

Costs And When To Call A Pro

Repeated use of a heat pump reset button is a warning. Continuing to reset a tripping system can damage the compressor. Know the signs that require professional service and typical costs.

  • Call Immediately If: Breakers trip repeatedly, burning smells occur, the outdoor fan does not run, ice persists, or the reset trips again within minutes.
  • What A Tech Does: Read board codes, test capacitors/contactors, verify blower operation, measure pressures and temperatures, check superheat/subcooling, inspect coils, confirm defrost operation, and locate leaks.
  • Typical Costs (National Averages): Service call/diagnostic: $100–$200; run capacitor: $150–$400 installed; contactor: $150–$300; blower motor: $400–$1,000; defrost board: $300–$600. Refrigerant leak repair varies widely; R-410A top-ups often $125–$250 per lb plus repair.

Technicians also ensure compliance with evolving refrigerants (R‑410A and newer lower-GWP blends) and safe handling. DIY charging is not recommended.

Maintenance That Prevents Resets

Proactive care reduces the chance of ever needing a heat pump reset button. Routine tasks improve efficiency, comfort, and equipment life.

  • Filters: Replace every 1–3 months or per MERV rating and household conditions.
  • Outdoor Unit: Keep 18–24 inches of clearance. Trim plants, remove leaves, and gently clean coils in spring and fall.
  • Indoor Coil & Drain: Have a pro clean coils as needed. Flush condensate lines annually; consider a float switch.
  • Electrical: Ask about a HVAC surge protector. Loose connections and surges can trigger lockouts.
  • Tune-Ups: Semiannual maintenance checks refrigerant charge, electrical health, and defrost performance.
  • Thermostat Settings: Avoid large setbacks that cause rapid cycling. Enable compressor protection delays.
  • Ductwork: Seal leaks and verify airflow. Low airflow is a common cause of high-pressure trips.

Heat Pump Reset Button: FAQs

Where Is The Heat Pump Reset Button?

Some systems include a manual high-pressure reset on the outdoor unit or a blower thermal reset on the air handler. Many newer heat pumps have no physical reset and rely on a power cycle to clear lockouts.

How Do You Reset A Heat Pump Without A Button?

Turn the thermostat OFF, switch the breaker and outdoor disconnect OFF, wait 5 minutes, then restore power. Set the thermostat back to HEAT or COOL and allow time delays to pass.

Why Does My Heat Pump Keep Tripping The Reset Or Breaker?

Likely causes include dirty coils, a bad fan or capacitor, restricted airflow, overcharge/undercharge, or an electrical short. Stop resetting and schedule service if it happens more than once.

How Long Should I Wait After Powering Off?

Wait at least 5 minutes for compressor pressure equalization and control-board reset. Some thermostats impose a 3–10 minute delay before restart.

Is It Safe To Press The High-Pressure Reset Repeatedly?

No. A single reset after fixing airflow may be fine. Repeated trips indicate a problem that can damage the compressor or fan if ignored.

Do Mini-Splits Have A Reset Button?

Most do not have an outdoor reset button. They use error codes and controller resets. Power cycling and reviewing the error code is the first step.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

Will Resetting Delete Error Codes?

Power cycling can clear active codes. Photograph LED codes or controller messages before resetting to help technicians diagnose issues.

What If The Outdoor Unit Is Silent After Reset?

It may be in a time delay, or the contactor/capacitor may be failed. Ensure the thermostat calls for cooling/heating. If still silent after 10 minutes, call a pro.

Brand And Model Notes

Brands design safety and reset differently. Always check the installation or user manual for model-specific guidance to avoid missteps.

  • Carrier/Bryant/Payne: Some models use auto-reset pressure switches and board lockouts with LED codes. Power cycle to clear, note codes first.
  • Trane/American Standard: Manual HP resets appear on select legacy units; newer boards often auto-reset with delays.
  • Lennox/Armstrong/Aire-Flo: Mixed use of manual resets; coil cleanliness is critical to avoid HP trips.
  • Mitsubishi/Daikin/Fujitsu/LG (Ductless): Follow error code charts. Use controller reset and power cycle rather than searching for a physical button.

Helpful Resources

Official guides provide deeper background on safe operation, maintenance, and efficiency. Use reputable sources to avoid risky advice.

Symptom-To-Cause Quick Reference

Symptom Likely Causes Homeowner Action
Trips Immediately After Reset Shorted capacitor, seized fan, severe restriction Turn OFF and call a pro; do not keep resetting
Outdoor Unit Runs Hot, Loud Dirty outdoor coil, failed fan, overcharge Clean coil, ensure clearance; service if persists
Ice On Indoor Coil Dirty filter, low airflow, low refrigerant Replace filter, run FAN to defrost; call if recurring
No Airflow Indoors Blower thermal trip, float switch, failed motor Reset blower (if present), check drain; call if no start
Breaker Trips Electrical short, compressor start issues Do not reset repeatedly; schedule service
Short Cycling Thermostat settings, oversized system, low charge Adjust min run-time; request professional evaluation

Key Takeaways For The Heat Pump Reset Button

  • Not Every Heat Pump Has One: Many rely on power cycling to clear lockouts.
  • Use Resets Sparingly: One reset after correcting airflow is reasonable; repeat trips mean service.
  • Safety First: Power off before pressing any button. Never bypass safeties.
  • Fix The Cause: Filters, coils, fans, and drains are common culprits behind trips.
  • Document Codes: Note LED flashes or controller messages before resetting.

SEO Note: Related Searches And Terms

Users also search “where is the reset button on a heat pump,” “how to reset heat pump,” “heat pump high-pressure switch reset,” “reset outdoor unit,” “thermostat reset,” “mini-split reset,” and “heat pump keeps tripping breaker.” These terms tie to the guidance above on safe power cycling, locating manual resets, and diagnosing repeated trips.

How to Get the Best HVAC Prices

  • Firstly, keep in mind that installation quality is always the most important thing for residential HVAC project. So never sacrifice contractor quality for a lower price.
  • Secondly, remember to look up the latest rebates as we talked above.
  • Thirdly, ask for at least 3 bids before you make the decision. You can click here to get 3 free estimates from your local contractors, and this estimate already takes rebates and tax credit into consideration and filter unqualified contractors automatically.

Lastly, once you chose the right contractor, remember to use the tactics from this guide: Homeowners Tactics When Negotiating with HVAC Dealer to get the final best price.

Written by

Rene has worked 10 years in the HVAC field and now is the Senior Comfort Specialist for PICKHVAC. He holds an HVAC associate degree and EPA & R-410A Certifications.
Share Your HVAC Quote/Cost

Share Your HVAC Quote/Cost

We rely on readers like you to share your HVAC system cost or quote. It really helps other visitors to estimate the cost of a new HVAC unit.

Optional
Optional
ie: Tranx XR13, Lennox xp15
Include Ductwork Replacement? *
Sending

DMCA.com Protection Status