Heat Pump Efficiency vs Temperature: Performance in Cold and Warm Weather

Heat pump efficiency vs temperature is one of the most important factors that determines comfort, operating cost, and carbon impact. As outdoor conditions change, so does a heat pump’s coefficient of performance (COP), capacity, and runtime. This guide explains how temperature affects both heating and cooling efficiency, what real-world numbers look like, and practical ways to get the best results in U.S. climates.

Heat pumps move heat, not create it. As the temperature difference between outdoors and indoors grows, the system works harder. In winter, colder air contains less usable heat and the compressor must lift temperature more. In summer, hotter air makes it harder for the system to reject heat outdoors.

Heating Mode: COP Vs Outdoor Temperature

At mild winter temperatures (around 47°F), many air-source heat pumps (ASHPs) achieve COPs between 3.0 and 4.5. As outdoor temperature drops toward freezing, typical COP declines into the 2–3 range. In very cold air, COP can approach 1–2, especially for older or standard units.

Cold-climate air-source heat pumps (CC-ASHPs) use variable-speed inverters, optimized refrigerants, larger coils, and advanced controls. Many retain more capacity and deliver higher COP at 17°F, 5°F, and sometimes below 0°F compared with standard models.

Capacity also falls with outdoor temperature. A heat pump sized for cooling or shoulder-season heating may not meet design load at the coldest “design day,” triggering longer runtimes or electric resistance backup. Keeping capacity and COP at low temperatures is the hallmark of cold-climate models.

Cooling Mode: SEER2/EER2 Vs Outdoor Temperature

In cooling, efficiency is also temperature-dependent. As outdoor temperatures climb above 95°F, the condenser rejects heat less effectively, reducing EER and increasing watt draw. Variable-speed systems help by modulating to match lower loads, running longer but more efficiently at part load.

SEER2 is a weighted seasonal average; EER2 is checked at 95°F. In heat waves, even high-SEER2 systems draw more power. Clean outdoor coils, adequate airflow, and shading can help maintain steady cooling efficiency across temperature spikes.

Air-Source Vs Ground-Source: Temperature Stability And Efficiency

Air-source heat pumps exchange heat with outdoor air. Because air temperature swings widely, their COP varies strongly with seasons and weather. Their efficiency is excellent in mild conditions and remains viable in cold weather when properly selected and installed.

Ground-source (geothermal) heat pumps exchange heat with earth or groundwater, which stays near 45–60°F in many U.S. regions. This stable source yields higher winter COP (often 3–5) and high cooling efficiency, with less seasonal efficiency swing. Upfront costs are higher, offset by reduced operating costs and possible incentives.

Water-source and lake/pond loop systems are specialized variations. Where feasible, these designs reduce temperature extremes faced by the heat pump, flattening the efficiency vs temperature curve.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

Cold-Climate Heat Pumps And Low-Temperature Performance

Manufacturers now offer CC-ASHPs that maintain meaningful capacity and reasonable COP well below freezing. Third-party listings like the NEEP Cold-Climate Air-Source Heat Pump Specification identify models with verified low-ambient capabilities.

Many CC-ASHPs retain 70–100% of rated capacity at 5°F and can operate at -5°F to -15°F, though COP will still drop. These systems use variable-speed compressors, vapor injection, optimized refrigerant circuits, and smart defrost to keep efficiency as high as conditions allow.

Key takeaway: Not all “heat pumps” perform the same in cold weather. Selecting a CC-ASHP for northern climates can substantially improve efficiency vs temperature and reduce reliance on electric resistance or fossil backup.

Typical COP And Capacity Trends By Temperature

The table below shows general ranges for modern residential systems. Actual performance depends on the exact model, installation, and duct or ductless configuration. Always consult manufacturer extended performance data for precise curves.

Outdoor Temperature (°F) Standard ASHP COP Cold-Climate ASHP COP Capacity Retention (Standard) Capacity Retention (Cold-Climate)
50 3.5–4.5 4.0–5.0 100% 100%
47 3.0–4.0 3.5–4.5 100% 100%
32 2.2–3.0 2.7–3.6 80–95% 90–100%
17 1.7–2.4 2.2–3.0 60–85% 80–100%
5 1.4–2.0 1.8–2.6 40–75% 70–95%
-5 1.2–1.7 1.5–2.2 30–60% 60–90%

Interpretation: As temperature falls, both COP and output decline. Cold-climate models narrow the drop, raising efficiency at the temperatures that drive most heating energy use in northern states.

Defrost, Humidity, And Auxiliary Heat: Hidden Factors

Below ~40°F, outdoor coils can frost during heating. Periodically, the system reverses to cooling to melt ice, using indoor heat to defrost and then reheating the air. In humid, subfreezing weather, defrost can add 5–15% to energy use, sometimes more in sustained icing conditions.

Auxiliary electric resistance heat (strip heat) supplements capacity during low temperatures or rapid setpoint recovery. Its COP is ~1. Overuse—caused by aggressive setbacks, undersized equipment, or conservative thermostat settings—can mask the heat pump’s natural advantage.

Smart controls can reduce auxiliary reliance via outdoor lockout settings, staged heat, and gentle ramp strategies. In dual-fuel setups, a high-efficiency gas furnace can take over below an economic balance point to minimize operating cost or emissions based on local rates and priorities.

Sizing, Balance Point, And Thermostat Strategy

Balance point is the outdoor temperature at which the heat pump’s capacity equals the home’s heat loss. Below that point, backup heat is needed. Lowering a home’s heat loss through insulation, air sealing, and duct sealing reduces the required capacity and lowers the balance point, improving efficiency in colder weather.

Right-sized, variable-speed equipment runs longer at low power, improving dehumidification in summer and maintaining higher COP in winter. Overlarge systems short-cycle, defrost more often, and may rely on backup heat sooner in cold snaps.

Thermostat strategy matters. In heating, avoid large nighttime setbacks during very cold weather, which can trigger resistance heat. A small setback (e.g., 2–3°F) or none is often best. In cooling, moderate setbacks and smart schedules typically save energy without comfort penalties.

Regional Climate And Real-World Efficiency

Energy use depends on how many hours your location spends at each temperature. This is the “bin” method used in ratings like HSPF2. A heat pump’s seasonal efficiency will be higher in the Mid-Atlantic than in northern Minnesota, even with the same equipment and house.

In the Southeast and Pacific Coast, winter temperatures are often in the 30s and 40s, where COP is high. In the Northeast and Upper Midwest, modern CC-ASHPs keep COP well above resistance heat most of the winter, but defrost and very low temperatures make design and setup more critical.

In cooling-dominant climates, a heat pump’s SEER2 and part-load performance (inverter or two-stage) drive comfort and bills. Roof and attic temperatures, duct location, and humidity control can shift real-world efficiency more than small differences in nameplate SEER2.

Practical Ways To Maximize Efficiency Across Temperatures

  • Choose The Right Type: In colder climates, consider a NEEP-listed cold-climate air-source heat pump or ground-source system. Ductless minisplits often excel at low temperatures and in retrofit applications.
  • Size For The Load: Use a room-by-room Manual J heat loss/gain and review manufacturer extended performance tables. Aim for right-sized or slightly conservative capacity with variable speed for shoulder seasons and cold snaps.
  • Optimize Airflow: Match ducts to the new system’s static pressure. SEER2/HSPF2 tests assume higher external static. Poor airflow lowers COP, increases defrost frequency, and raises noise.
  • Set Thermostat Intelligently: Use a heat-pump-aware thermostat. Enable outdoor temperature lockouts for strip heat. Avoid big heating setbacks in cold weather; use gradual ramping.
  • Reduce The Load: Air seal, insulate attics and walls, and seal/insulate ducts—especially in attics or crawlspaces. Lower loads reduce runtime and drop the balance point, improving efficiency vs temperature.
  • Maintain The System: Change filters regularly, clean indoor and outdoor coils, and keep the outdoor unit clear of snow and debris. Correct refrigerant charge and sensor calibration matter at low ambient.
  • Manage Defrost: Ensure proper condensate drainage and open airflow around the outdoor unit. In humid freezing conditions, occasional manual snow removal helps prevent long defrost cycles.
  • Use Mild Weather Wisely: In shoulder seasons, let the unit run longer at low capacity for high COP. Avoid switching to resistance space heaters—they have COP ≈1 and raise bills.

Example: How Bills Change As Temperature Drops

Consider a home needing 28,000 Btu/h at 17°F and 18,000 Btu/h at 30°F. The heat pump can produce 16,000 Btu/h at 17°F with COP 2.0, and it meets the whole 18,000 Btu/h at 30°F with COP 3.0. Electricity costs $0.16/kWh.

At 30°F: 18,000 Btu/h ÷ (3 × 3,412) ≈ 1.76 kW. Per hour cost ≈ $0.28. Over 10 hours at that temperature, ≈ $2.80.

At 17°F: Heat pump delivers 16,000 Btu/h at COP 2.0, drawing 16,000 ÷ (2 × 3,412) ≈ 2.35 kW. The extra 12,000 Btu/h comes from electric resistance: 12,000 ÷ 3,412 ≈ 3.52 kW. Total ≈ 5.87 kW, or $0.94 per hour. Over 10 hours, ≈ $9.40.

Insight: As temperature falls, both COP and capacity drop, and backup heat may run—sharply increasing kWh. Selecting a cold-climate model, improving the envelope, and optimizing controls can keep more of the load on the high-COP heat pump.

Heat Pump Efficiency Vs Temperature: Key FAQs

At What Temperature Do Heat Pumps Stop Being Efficient?

Heat pumps remain more efficient than resistance heat down to well below freezing. Many CC-ASHPs deliver COP above 2 near 5°F and continue to operate below 0°F. Efficiency does decline with temperature, so overall operating cost depends on COP, local rates, and how often your climate hits those temperatures.

What About Below 0°F?

Some CC-ASHPs maintain capacity down to -5°F to -15°F with COP around 1.5–2.2. Performance varies by model. Below the unit’s minimum, it may shut off or rely on auxiliary heat. Manufacturer data and independent cold-climate listings are the best guide.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

How Does Humidity Affect Efficiency?

In cold, humid weather, frost on the outdoor coil increases defrost frequency, reducing net COP. In hot, humid summers, variable speed helps by running longer at lower output to dehumidify efficiently, often at a higher part-load efficiency than short, high-speed cycles.

Is A Dual-Fuel System More Efficient In Cold Weather?

It can be, depending on energy prices and emissions goals. If natural gas is inexpensive and electricity is carbon-intensive, a high-efficiency furnace may be cheaper below an economic balance point. If electricity is clean and rates favorable, staying on a CC-ASHP may be best. Smart thermostats can automate the switchover.

How Do Ductless Minisplits Perform In Cold Weather?

Many ductless CC-ASHPs have excellent low-temperature performance and high COP at part load. They avoid duct losses and can target rooms with high loads or addition spaces. Multi-zone systems need careful design to maintain coil temps and avoid short cycling in mild weather.

Do Ground-Source Heat Pumps Always Win?

Ground-source systems typically deliver higher and more stable COP across seasons thanks to moderate ground temperatures. They often “win” on operating efficiency but have higher upfront costs and site constraints. Incentives and long runtimes in cold climates can tip the economics in their favor.

Cooling Efficiency And Heat Waves

When outdoor temperatures surge above 95°F, cooling EER drops as the condenser works against higher ambient temperature. A clean, shaded outdoor unit with unrestricted airflow can reduce discharge pressures and protect efficiency.

Variable-speed units excel at part-load conditions, which dominate most of the cooling season. In real homes, proper airflow, balanced refrigerant charge, and duct sealing can produce larger savings than small differences in nameplate SEER2.

Interpreting Ratings And Performance Data

Look for HSPF2 for heating and SEER2/EER2 for cooling on the yellow EnergyGuide label. Cold-climate units often advertise low-ambient capacity (e.g., “100% at 5°F”). Verify with manufacturer extended performance tables that include COP and capacity across outdoor temperatures and indoor setpoints.

ENERGY STAR highlights efficient models and publishes key specs, while Energy Star and U.S. DOE resources explain terminology and incentives. AHRI directories provide certified ratings for matched systems, ensuring the indoor and outdoor units are tested together.

Real-World Installation Details That Shape The Curve

Duct losses in attics or garages can erode seasonal efficiency. Sealing and insulating ducts can improve both winter COP and summer EER. Right-size registers and balance dampers to ensure adequate airflow at low compressor speeds.

Outdoor unit placement affects icing and airflow. Elevate above snow lines, avoid roof drip zones, and keep at least 12–24 inches clearance around the coil face. A wind baffle may help in very windy sites if permitted by the manufacturer.

Refrigerant charge and sensors must be verified. Undercharge or overcharge reduces efficiency and capacity, especially at temperature extremes. Commissioning steps—like weighing in charge, checking superheat/subcooling, and confirming thermistor calibration—directly influence COP vs temperature.

When To Consider Upgrades

If an older system struggles below freezing, a cold-climate replacement can reduce auxiliary use and improve comfort. Where ducts are constrained, targeted ductless heads in the main living area can carry most of the heating load, leaving existing equipment for bedrooms or backup.

For homes planning major electrification, a whole-house Manual J and duct assessment paired with weatherization yields a better outcome than a like-for-like swap. In many U.S. regions, incentives and tax credits ease the cost of higher-performance models and envelope improvements.

Glossary Of Key Terms

  • COP (Coefficient Of Performance): Heat output divided by electrical input; higher is better.
  • HSPF2: Heating seasonal efficiency under the latest M1 test procedure; Btu/Wh.
  • SEER2/EER2: Cooling seasonal/steady-state efficiency metrics under M1.
  • CC-ASHP: Cold-climate air-source heat pump with verified low-ambient performance.
  • Balance Point: Outdoor temperature where heat pump output equals home heat loss.
  • Auxiliary Heat: Typically electric resistance strips; COP ≈1.
  • Defrost: Temporary reverse-cycle operation to melt frost on the outdoor coil.

Key Numbers And Rules Of Thumb

  • At 47°F: Many ASHPs deliver COP ~3–4; capacity near nameplate.
  • Around 32°F: COP often 2–3; watch for defrost impacts in humid air.
  • At 17°F: Standard COP may be 1.7–2.4; cold-climate 2.2–3.0; capacity often 60–100% depending on model.
  • At 5°F And Below: CC-ASHPs can maintain 70–95% capacity with COP roughly 1.8–2.6; standard units may need more backup.
  • Electric Resistance: COP ≈1; kept as backup only when needed.
  • Ground-Source: COP often 3–5 across winter due to stable ground temperature.

Helpful Standards And Resources

For product comparisons and specification details, consult these authoritative sources:

Bottom Line For Heat Pump Efficiency Vs Temperature

Heat pump efficiency depends strongly on outdoor temperature. At mild temperatures, COP is highest; at deep-cold conditions, COP and capacity fall. Cold-climate designs, correct sizing, careful installation, and smart controls minimize the drop and reduce auxiliary heat use. Upgrades to insulation and ducts amplify the benefit at every temperature.

Don’t Overpay for HVAC Services – Call 888-894-0154 Now to Compare Local Quotes!

With the right equipment and setup, modern heat pumps deliver efficient, comfortable heating in most U.S. climates and efficient cooling during heat waves—proving that understanding efficiency vs temperature is the key to better performance, lower bills, and cleaner energy.

How to Get the Best HVAC Prices

  • Firstly, keep in mind that installation quality is always the most important thing for residential HVAC project. So never sacrifice contractor quality for a lower price.
  • Secondly, remember to look up the latest rebates as we talked above.
  • Thirdly, ask for at least 3 bids before you make the decision. You can click here to get 3 free estimates from your local contractors, and this estimate already takes rebates and tax credit into consideration and filter unqualified contractors automatically.

Lastly, once you chose the right contractor, remember to use the tactics from this guide: Homeowners Tactics When Negotiating with HVAC Dealer to get the final best price.

Written by

Rene has worked 10 years in the HVAC field and now is the Senior Comfort Specialist for PICKHVAC. He holds an HVAC associate degree and EPA & R-410A Certifications.